135 |
/**********************************************************************/ |
/**********************************************************************/ |
136 |
// TODO: Add extra initialization here |
// TODO: Add extra initialization here |
137 |
|
|
138 |
// Sets values in baud-rate combo box |
ServerInit(); |
|
m_BaudRate.AddString("1200"); |
|
|
m_BaudRate.AddString("2400"); |
|
|
m_BaudRate.AddString("4800"); // Don't work, used for error test. |
|
|
m_BaudRate.AddString("9600"); |
|
|
m_BaudRate.AddString("19200"); |
|
|
|
|
|
// Checks how many COM ports there are. |
|
|
std::vector<CString> Serial = GetAvailableComPorts(); |
|
|
for (unsigned int i=0; i<Serial.size(); i++) |
|
|
m_Serial.AddString(Serial[i]); |
|
|
m_Serial.SetCurSel(0); |
|
|
|
|
|
// Load saved settings from regedit. |
|
|
unsigned long Port; |
|
|
unsigned long BaudRate; |
|
|
// CString LoadCom; |
|
|
|
|
|
// Used to format the loaded values. |
|
|
CString TPort; |
|
|
CString TBaudRate; |
|
|
|
|
|
CRegKey reg; |
|
|
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
|
|
reg.QueryDWORDValue("Port", Port); |
|
|
reg.QueryDWORDValue("BaudRate", BaudRate); |
|
|
|
|
|
char LoadCom[20]; |
|
|
unsigned long size = 20; |
|
|
reg.QueryStringValue("Serial", LoadCom, &size); |
|
|
|
|
|
TPort.Format("%d", Port); |
|
|
TBaudRate.Format("%d", BaudRate); |
|
|
// TLoadCom.Format("%s", TLoadCom); |
|
139 |
|
|
|
m_Port.SetWindowText(TPort); |
|
|
m_BaudRate.SetWindowText(TBaudRate); |
|
|
m_Serial.SetWindowText(LoadCom); |
|
|
MessageBox(LoadCom); |
|
140 |
/**********************************************************************/ |
/**********************************************************************/ |
141 |
return TRUE; // return TRUE unless you set the focus to a control |
return TRUE; // return TRUE unless you set the focus to a control |
142 |
} |
} |
192 |
|
|
193 |
void CH7ServerDlg::OnBnClickedStart() |
void CH7ServerDlg::OnBnClickedStart() |
194 |
{ |
{ |
195 |
|
// Get TCp port |
196 |
CRegKey reg; |
CRegKey reg; |
197 |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
198 |
unsigned long Port; |
unsigned long Port; |
199 |
reg.QueryDWORDValue("Port", Port); |
reg.QueryDWORDValue("Port", Port); |
200 |
|
|
201 |
CString tmp; |
// Add's user defined Baud-Rate to regedit before the server start. |
202 |
tmp.Format("%d", Port); |
CString Baud; |
203 |
m_Port.SetWindowText(tmp); |
m_BaudRate.GetWindowText(Baud); |
204 |
|
reg.SetDWORDValue("BaudRate", atoi(Baud) ); |
205 |
|
|
206 |
|
StartTcp(); |
207 |
} |
} |
208 |
|
|
209 |
int CH7ServerDlg::StartTcp(void) |
int CH7ServerDlg::StartTcp(void) |
210 |
{ |
{ |
211 |
|
// Gets the TCP Port number from regedit. |
212 |
unsigned long Port; |
unsigned long Port; |
213 |
CRegKey reg; |
CRegKey reg; |
214 |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
215 |
reg.QueryDWORDValue("Port", Port); |
reg.QueryDWORDValue("Port", Port); |
216 |
|
reg.Close(); |
217 |
|
|
218 |
|
// Restats the TCP Connection |
219 |
TcpServer.Close(); |
TcpServer.Close(); |
220 |
|
|
221 |
TcpServer.Create(Port); |
TcpServer.Create(Port); |
222 |
TcpServer.Listen(); |
TcpServer.Listen(); |
223 |
|
|
224 |
|
// Prints TCP Port number to the status box. |
225 |
|
CString tmp; |
226 |
|
tmp.Format("%d", Port); |
227 |
|
m_Port.SetWindowText(tmp); |
228 |
|
|
229 |
return 0; |
return 0; |
230 |
} |
} |
231 |
|
|
232 |
void CH7ServerDlg::OnBnClickedTest() |
void CH7ServerDlg::OnBnClickedRestart() |
233 |
{ |
{ |
234 |
//**************** <TCP Port section> ****************/ |
CWaitCursor wait; // Musen viser timeglas. |
235 |
CString Port = ""; |
CString Port; |
|
|
|
236 |
m_Port.GetWindowText(Port); |
m_Port.GetWindowText(Port); |
|
// Saving Port number in regedit as int |
|
237 |
CRegKey reg; |
CRegKey reg; |
238 |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
239 |
reg.SetDWORDValue("Port", atoi(Port) ); |
reg.SetDWORDValue("Port", atoi(Port) ); |
240 |
|
|
241 |
|
CString tmp; |
242 |
|
m_Serial.GetWindowText(tmp); |
243 |
|
reg.SetStringValue("Serial",tmp); |
244 |
reg.Close(); |
reg.Close(); |
|
// Debug info to the status edit box. |
|
|
m_Status.SetWindowText(Port); |
|
|
//**************** </TCP Port section> ****************/ |
|
245 |
StartTcp(); |
StartTcp(); |
246 |
} |
} |
247 |
|
|
248 |
|
void CH7ServerDlg::OnBnClickedTest() |
|
void CH7ServerDlg::OnBnClickedRestart() |
|
249 |
{ |
{ |
250 |
CWaitCursor wait; // Musen viser timeglas. |
|
251 |
CString Port; |
} |
252 |
m_Port.GetWindowText(Port); |
void CH7ServerDlg::ServerInit(void) |
253 |
|
{ |
254 |
|
int i; |
255 |
CRegKey reg; |
CRegKey reg; |
256 |
|
// Sets values in baud-rate combo box |
257 |
|
m_BaudRate.AddString("1200"); |
258 |
|
m_BaudRate.AddString("2400"); |
259 |
|
m_BaudRate.AddString("4800"); // Don't work, used for error test. |
260 |
|
m_BaudRate.AddString("9600"); |
261 |
|
m_BaudRate.AddString("19200"); |
262 |
|
|
263 |
|
unsigned long Baud; |
264 |
|
CString GetBaud; |
265 |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
266 |
reg.SetDWORDValue("Port", atoi(Port) ); |
reg.QueryDWORDValue("BaudRate", Baud); |
267 |
StartTcp(); |
|
268 |
|
switch (Baud) |
269 |
|
{ |
270 |
|
case 1200: |
271 |
|
m_BaudRate.SetCurSel(0); |
272 |
|
break; |
273 |
|
case 2400: |
274 |
|
m_BaudRate.SetCurSel(1); |
275 |
|
break; |
276 |
|
case 4800: |
277 |
|
m_BaudRate.SetCurSel(2); |
278 |
|
break; |
279 |
|
case 9600: |
280 |
|
m_BaudRate.SetCurSel(3); |
281 |
|
break; |
282 |
|
case 19200: |
283 |
|
m_BaudRate.SetCurSel(4); |
284 |
|
break; |
285 |
|
default: |
286 |
|
m_BaudRate.SetCurSel(3); |
287 |
|
break; |
288 |
|
} |
289 |
|
|
290 |
|
m_BaudRate.GetWindowText(GetBaud); |
291 |
|
reg.SetDWORDValue("BaudRate", atoi(GetBaud) ); |
292 |
|
|
293 |
|
// Checks how many COM ports there are. |
294 |
|
std::vector<CString> Serial = GetAvailableComPorts(); |
295 |
|
for (i=0; i<Serial.size(); i++) |
296 |
|
m_Serial.AddString(Serial[i]); |
297 |
|
|
298 |
|
// Load saved settings from regedit. |
299 |
|
unsigned long Port; |
300 |
|
unsigned long BaudRate; |
301 |
|
|
302 |
|
// Used to format the loaded values. |
303 |
|
CString TPort; |
304 |
|
CString TBaudRate; |
305 |
|
|
306 |
|
reg.Create(HKEY_LOCAL_MACHINE, "SOFTWARE\\Projekt\\Server"); |
307 |
|
reg.QueryDWORDValue("Port", Port); |
308 |
|
reg.QueryDWORDValue("BaudRate", BaudRate); |
309 |
|
|
310 |
|
char LoadCom[20]; |
311 |
|
unsigned long size = 20; |
312 |
|
reg.QueryStringValue("Serial", LoadCom, &size); |
313 |
|
|
314 |
|
TPort.Format("%d", Port); |
315 |
|
TBaudRate.Format("%d", BaudRate); |
316 |
|
|
317 |
|
m_Port.SetWindowText(TPort); |
318 |
|
m_BaudRate.SetWindowText(TBaudRate); |
319 |
|
m_Serial.SetWindowText(LoadCom); |
320 |
|
|
321 |
|
// Checks for valid COM port in regedit. |
322 |
|
for (i=0; i< Serial.size() ; i++) |
323 |
|
{ |
324 |
|
if (LoadCom == Serial[i]) |
325 |
|
{ |
326 |
|
m_Serial.SetCurSel(i); |
327 |
|
break; |
328 |
|
} |
329 |
|
} |
330 |
|
if (i == Serial.size() ) |
331 |
|
{ |
332 |
|
m_Serial.SetCurSel(0); |
333 |
|
reg.SetStringValue("Serial", Serial[0]); |
334 |
|
} |
335 |
|
reg.Close(); |
336 |
|
|
337 |
} |
} |